U-Line Refrigerator freezer is cold but refrigerator is warm
The Evaporator Coils are Frosted Over
The defrost heater assembly turns on a few times throughout the day to melt away any frost that may have accumulated on the evaporator coils. If the defrost heater assembly is defective, frost will continue to accumulate on the evaporator coils, and the coils will become plugged with frost. If the evaporator coils are frosted over, the airflow through the coils will be restricted, causing the refrigerator not to cool. Check the evaporator coils to determine if they are frosted over. If the evaporator coils are frosted over, test each component of the defrost system.
U-Line Refrigerator Evaporator Fan Motor
The evaporator fan motor draws cold air over the evaporator coils and circulates it throughout the freezer. If the evaporator fan is not working, the freezer or refrigerator will not cool adequately. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Door not closing all the way
If a door is slightly open, the refrigerator may not cool properly. The door bin may be hitting the shelf causing the door to stay slightly open. Food Items in the door bins and shelves can also keep the door from closing. Make sure the shelves and door bins are in the proper locations. Avoid overloading the door bins and shelves.
U-Line Refrigerator Temperature Control Thermostat
The temperature control thermostat directs voltage to the compressor, evaporator fan motor, and condenser fan motor (if applicable). If the temperature control thermostat is not working properly, it may prevent the refrigerant system from running properly, resulting in the refrigerator compartment not cooling as expected. To determine if the thermostat is defective, rotate the thermostat from the lowest setting to the highest setting and listen for a click. If the thermostat clicks, it is not likely defective. If the thermostat does not click, use a multimeter to test the thermostat for continuity. If the temperature control thermostat does not have continuity at any setting, replace it.
U-Line Refrigerator Door Gasket
A refrigerator door gasket should form an airtight seal around the appliance’s frame to keep the cold air in and the warm air out. If the door gasket is twisted or torn, gaps can form that will allow warm air in, resulting in the refrigerator compartment being warm even though the freezer compartment is cold. Inspect the door gasket for any damage and replace with a new one if necessary.
U-Line Refrigerator Damper Control Assembly
The air damper control opens and closes to let the proper amount of cold air into the refrigerator compartment. If the damper does not open properly, it won’t let enough cold air into the refrigerator. Check the damper control to determine if it is broken or stuck closed.
U-Line Refrigerator Thermistor
The thermistor monitors the refrigerator temperature and sends the temperature reading to the control board. The control board then regulates power to the compressor and evaporator fan based on the thermistor readings. If the thermistor is defective, the compressor and evaporator fan may not run when necessary, or may run too frequently. To determine if the thermistor is defective, test it with a multimeter. The thermistor resistance should change in conjunction with the refrigerator temperature. If the thermistor resistance does not change, or the thermistor does not have continuity, replace the thermistor.
U-Line Refrigerator Defrost Heater Assembly
The defrost heater assembly turns on several times throughout the day to melt away any frost that may have accumulated on the evaporator coils. If the defrost heater assembly is defective, the defrost system will not work, and frost will continue to accumulate on the evaporator coils. This will result in cooling problems where the freezer compartment might appear to be cold but the refrigerator compartment is warm. To determine if the defrost heater is defective, use a multimeter to test it for electrical continuity. If the defrost heater does not have continuity, replace it.
U-Line Refrigerator Temperature Control Board
The temperature control board provides voltage to the compressor and fan motors. If the control board is faulty, it may stop sending voltage to the compressor or fan motors. Control boards are often misdiagnosed—before replacing the control board, first test all of the more commonly defective components. If none of the other components are defective, consider replacing the temperature control board.
U-Line Refrigerator Defrost Thermostat
The defrost thermostat monitors the temperature of the evaporator coils. When the coils drop below a set temperature, the thermostat contacts close to allow power to flow to the defrost heater during the defrost cycle. In the defrost cycle, the defrost heater melts away any frost that may have accumulated on the evaporator coils. If the defrost thermostat is defective, the defrost heater may not activate. This will cause the evaporator coils to frost over which can result in cooling problems where the freezer compartment might appear to be cold but the refrigerator compartment is warm. To determine if the defrost thermostat is defective, use a multimeter to test it for electrical continuity. If the defrost thermostat does not have continuity when it reaches the low temperature of its operating range, replace it.
U-Line Refrigerator Defrost Control Board
The defrost control board determines how often to run the defrost cycle. If the defrost control board fails, the refrigerator will not run the defrost cycle, and frost will continue to accumulate on the evaporator coils. If the evaporator coils are frosted over, the refrigerator will work harder to remove heat. As a result, the refrigerator may be too warm. If the defrost thermostat and defrost heater are working properly, the defrost control board is likely defective and will need to be replaced.
U-Line Refrigerator Defrost Timer
The defrost timer turns on the defrost heater several times throughout the day to melt any frost that may have accumulated on the evaporator coils. If the defrost timer is defective, it might not advance into the defrost cycle, or it might not send power to the defrost heater during the defrost cycle. If the defrost system isn’t working, frost will continue to accumulate on the evaporator coils, and the refrigerator will have to work harder to remove heat. As a result, the refrigerator may be too warm. To determine if the defrost timer is defective, slowly advance the dial into the defrost cycle. The compressor should turn off and the heater should turn on. If the timer does not send power to the defrost components or advance out of the defrost cycle within 30 minutes, this indicates that the defrost timer is not advancing. If the defrost timer is not advancing, replace it.
U-Line Refrigerator Main Control Board
The main control board might be defective. However, the control board is very rarely the cause of the problem. Before replacing the control board, first test all of the more commonly defective components. If none of these components are defective, consider replacing the main control board.
U-Line Refrigerator Control Board
The control board might be defective. However, the control board is very rarely the cause of the problem. Before replacing the control board, first test all of the more commonly defective components. If none of these components are defective, consider replacing the control board.
U-Line Refrigerator Damper Control
The air damper control opens and closes to let the proper amount of cold air into the refrigerator compartment. If the damper does not open properly, it won’t let enough cold air into the refrigerator. Check the damper control to determine if it is broken or stuck closed.