Maytag Dishwasher Error Codes
Maytag has long been a household name, known for manufacturing robust and efficient home appliances. Their dishwashers are no exception, combining advanced technology with user-friendly features to make kitchen chores a breeze.
In our blog, we delve into the realm of Maytag Dishwasher Error Codes, unraveling the mysteries behind these signals. We understand the frustration that comes with a malfunctioning dishwasher, but fear not – our adept professionals at Appliance Repair Los Angeles are here to guide you through troubleshooting and resolution.
Error Code |
Causes |
1-1 or F1E1 |
Stuck relay on the electronic control board Learn More |
1-2 of F1E2 |
Defective electronic control board Learn More |
2-1 or F2E1 |
Stuck button on the user interface control Learn More |
3-1 or F3E1 |
Thermistor/OWI sensor failure Learn More |
3-2 or F3E2 |
Shorted thermistor/OWI sensor Learn More |
3-3 or F3E3 |
OWI failed to calibrate or the drain hose check valve failed, allowing dirty water to back-flow into the dishwasher Learn More |
4-4 or F4E4 |
Communication error between the electronic control board and the circulation pump motor Learn More |
5-1 or F5E1 |
Door switch failure Learn More |
5-2 or F5E2 |
Control detects door not opening Learn More |
6-1 or F6E1 |
Won’t fill Learn More |
6-2 or F6E2 |
Water inlet valve failure Learn More |
6-3 or F6E3 |
Suds or air are in the water pump Learn More |
6-4 or F6E4 |
The float switch is open Learn More |
6-7 or F6E7 |
Disconnected or damaged flow meter Learn More |
6-8 or F6E8 |
Problem with water softener regeneration valve (Water Softener Models Only) Learn More |
7-1 or F7E1 |
Heating element doesn’t work Learn More |
7-2 or F7E2 |
Heating element won’t shut off Learn More |
8-1 or F8E1 |
Slow drain Learn More |
8-2 or F8E2 |
Drain pump electrical problem Learn More |
8-4 of F8E4 |
Drain pump motor failure Learn More |
9-1 or F9E1 |
Electronic control board can’t detect the position of the diverter disc Learn More |
9-2 or F9E2 |
Diverter motor is stuck on Learn More |
9-3 or F9E3 |
Diverter disc is missing Learn More |
9-4 or F9E4 |
Lower spray arm error Learn More |
10-1 or FAE1 |
Detergent dispenser failure Learn More |
10-3 or FAE3 |
Drying fan failure Learn More |
12-1 or FCE1 |
Communication failure between the electronic control board and Wi-Fi module Learn More |
12-2 or FCE2 |
No link to the wireless router Learn More |
12-3 or FCE3 |
No internet connection Learn More |
12-5 or FCE5 |
Wi-Fi antenna failure Learn More |
Whether it’s decoding error codes, identifying faulty components, or executing precise repairs, Appliance Repair Los Angeles is your trusted partner for all Maytag dishwasher issues. We understand the urgency of a malfunctioning appliance, and our prompt and efficient service ensures that your kitchen gets back to its operational best in no time.
For immediate assistance with Maytag Dishwasher Error Codes, reach out to Appliance Repair Los Angeles at 323-792-1970. Our dedicated helpline is available to address your queries and schedule prompt service appointments.
Maytag Dishwasher Error Code 6-8 or F6E8
Encountering the Maytag Dishwasher Error Code 6-8 or F6E8 can be a perplexing situation, especially if you’re unsure about the underlying issue. This error specifically points to a problem with the water softener regeneration valve, applicable to models equipped with a water softener. Below, we guide you through a detailed understanding of the error and steps to resolve it effectively.
Error Description:
The error code 6-8 or F6E8 signifies a malfunction in the water softener regeneration valve, a critical component in models with integrated water softening capabilities. This valve is responsible for initiating the regeneration process that keeps your dishwasher’s water softening system operating efficiently.
- Wiring Issues: Faults in the wiring connected to the water softener regeneration valve.
- Valve Dysfunction: The water softener regeneration valve may be defective or failing.
Troubleshooting Steps:
1. Power Shutdown: The initial step involves turning off the power to your dishwasher. This ensures a safe environment for troubleshooting without the risk of electrical shock.
2. Wiring Inspection: Carefully examine the wiring connected to the water softener regeneration valve. Look for any visible signs of wear, damage, or loose connections. If the wiring appears intact, move on to the next step.
3. Water Softener Regeneration Valve Replacement: If the wiring checks out, the next course of action is to replace the water softener regeneration valve. This component is crucial for the proper functioning of the water softening system.
4. Electronic Control Board Replacement: If the issue persists even after replacing the regeneration valve, the next consideration is replacing the electronic control board. The control board acts as the brain of the dishwasher, coordinating various functions, and a malfunction can lead to error codes.
While these troubleshooting steps provide a comprehensive approach, it’s essential to acknowledge that dealing with electrical components requires expertise. Seeking professional assistance, such as from Appliance Repair Los Angeles, ensures a thorough diagnosis and precise resolution of the error. Professional technicians can assess the dishwasher’s components, perform necessary replacements, and guarantee the optimal functioning of your Maytag appliance.
In conclusion, addressing the Maytag Dishwasher Error Code 6-8 or F6E8 involves a systematic approach, from power shutdown to potential component replacements. Trusting the expertise of professionals ensures a swift and accurate resolution, allowing your dishwasher to regain its peak performance.
Maytag Dishwasher Error Code 6-7 or F6E7
Encountering the Maytag Dishwasher Error Code 6-7 or F6E7 can be a perplexing experience, signaling a potential issue with the flow meter. The flow meter plays a crucial role in measuring the water intake during the dishwasher’s operation, contributing to the efficiency of the entire system.
This error code points to a disconnected or damaged flow meter within your Maytag dishwasher. The flow meter is responsible for monitoring the water flow into the appliance, ensuring optimal performance and water usage. When this code appears, it suggests a disruption in the communication between the dishwasher and the flow meter.
1. Power Shutdown:
The first step in addressing this error is to shut off the power to the dishwasher. This ensures a safe environment for further inspection and potential repairs.
2. Wiring Inspection:
Carefully examine the wiring connected to the flow meter. Look for any visible signs of damage, wear, or disconnection. A secure and intact wiring connection is essential for proper communication between the dishwasher and the flow meter.
3. Replacement of Flow Meter:
If the wiring appears intact and the error persists, it is advisable to replace the flow meter. Damaged or malfunctioning flow meters can disrupt the dishwasher’s ability to regulate water flow, leading to operational issues.
In conclusion, the Maytag Dishwasher Error Code 6-7 or F6E7 underscores the importance of a properly functioning flow meter for seamless dishwasher operation. By following these steps, including a meticulous inspection of wiring and the potential replacement of the flow meter, you can restore your Maytag dishwasher to its optimal performance.
Maytag Dishwasher Error Code 6-4 or F6E4
Encountering the Maytag dishwasher error code 6-4 or F6E4 can be perplexing, but fear not – we’re here to guide you through understanding and resolving this issue. This error specifically points to a situation where the float switch is open, indicating a potential problem with the dishwasher’s water level regulation.
Understanding the Error:
When the dishwasher’s float switch is open, it means that the mechanism responsible for monitoring the water level is not in its proper position. This can occur if the float switch is stuck or if an object is obstructing its movement.
Troubleshooting Steps:
- Inspect the Float Switch:
- Begin by opening the dishwasher door and locating the float switch. It’s usually situated at the bottom of the dishwasher’s tub.
- Carefully examine the float switch to ensure it can move freely without any obstructions.
- Check for Obstructions:
- Look for any items, debris, or utensils that might be lodged underneath the float switch, preventing it from moving as intended.
- If any obstructions are found, carefully remove them to allow the float switch to function properly.
- Verify the Water Inlet Valve:
- Assess the water inlet valve to confirm that it is shutting off the water supply when the dishwasher is not in operation.
- A malfunctioning water inlet valve may lead to an overfill situation, triggering the float switch error.
Next Steps:
- After performing these checks, close the dishwasher door and restart the dishwasher to see if the error persists.
- If the issue continues, it is advisable to seek professional assistance. Certified technicians, such as those at Appliance Repair Los Angeles, can conduct a thorough examination of the float switch and related components to identify and address the root cause of the problem.
Maytag Dishwasher Error Code 6-3 or F6E3
Encountering the Maytag Dishwasher Error Code 6-3 or F6E3 can be perplexing, but fear not, as we guide you through understanding and resolving this issue. This error code signals that suds or air are present in the water pump, disrupting the normal operation of your dishwasher.
Error Description:
When excessive suds are detected in the water pump, it triggers the 6-3 or F6E3 error code. This scenario can impede the dishwasher’s ability to function optimally, leading to drainage issues and potential disruptions in the washing cycle.
Troubleshooting Steps:
- Identify Sudsy Water:
- Begin by visually inspecting the dishwasher for sudsy water. Excessive suds may be visible in the interior.
- If sudsy water is evident, it indicates a detergent-related issue that needs attention.
- Cancel the Cycle:
- To address the sudsy water concern, cancel the current dishwasher cycle. This action activates the drain pump for a 3-minute cycle to expel excess suds.
- Manual Draining:
- If the drain pump is unable to effectively remove the sudsy water, manual draining is recommended.
- Safely drain the water by hand or utilize a wet/dry shop vacuum to eliminate the sudsy water from the dishwasher interior.
Preventive Measures:
- Optimal Detergent Usage:
- Use the recommended amount of high-quality dishwasher detergent to avoid excessive suds formation.
- Ensure that the detergent used is specifically designed for dishwashers to prevent over-sudsing.
- Regular Maintenance:
- Periodically check for residue buildup, especially around the dishwasher door and gasket.
- Run a maintenance cycle with a dishwasher cleaner to keep the interior components free from soap scum and detergent residues.
If, after performing the above steps, the 6-3 or F6E3 error persists, it is advisable to seek professional assistance. Skilled technicians, such as those at Appliance Repair Los Angeles, can conduct a thorough examination, identify the root cause, and implement necessary repairs to restore your Maytag dishwasher to optimal performance.
Maytag Dishwasher Error Code 6-2 or F6E2
Encountering the Maytag Dishwasher Error Code 6-2 or F6E2 can be indicative of a water inlet valve failure, disrupting the seamless operation of your dishwasher. Here’s a comprehensive guide to understanding and resolving this issue.
Error Description:
The 6-2 or F6E2 error code signals a malfunction in the water inlet valve, a critical component responsible for allowing water to enter the dishwasher. When this error occurs, it’s essential to address the issue promptly to restore the dishwasher’s functionality.
Troubleshooting Steps:
-
Power Disconnection:
Begin by unplugging the dishwasher to ensure safety during the troubleshooting process.
-
Access Panels Inspection:
Remove the bottom front access panel and toe panel to gain access to the internal components of the dishwasher.
-
Wire Harness Examination:
- Check the wire harness connections on the water inlet valve for any signs of damage or disconnection.
- Reconnect any loose wires and inspect the overall condition of the wire harness.
-
Wire Harness Replacement:
If the wire harness is damaged beyond repair, it is advisable to replace it with a new one to ensure a secure and reliable connection.
-
Water Inlet Valve Resistance Check:
- Use a multimeter to measure the resistance of the water inlet valve.
- The expected reading should be around 1,400 ohms. If the multimeter shows infinite resistance, it indicates a faulty water inlet valve.
-
Water Inlet Valve Replacement:
If the water inlet valve is faulty, it is recommended to replace it with a new, functioning valve to restore proper water flow.
-
Electronic Control Board Evaluation:
- If the issue persists after addressing the water inlet valve, consider checking the electronic control board.
- A malfunctioning control board may be contributing to the error and may require replacement to ensure optimal dishwasher performance.
Addressing the Maytag Dishwasher Error Code 6-2 or F6E2 involves a systematic examination of the water inlet valve, wire harness, and electronic control board. Following these steps meticulously will help resolve the issue, restoring your dishwasher to its efficient functionality. If further assistance is needed, don’t hesitate to reach out to our expert technicians at Appliance Repair Los Angeles for professional diagnosis and resolution.
Maytag Dishwasher Error Code 6-1 or F6E1
Encountering the Maytag Dishwasher Error Code 6-1 or F6E1 signals a critical issue where the dishwasher refuses to fill with water, disrupting its normal operation. This error often stems from a variety of potential causes.
Firstly, it’s advisable to inspect the overfill float, a component designed to prevent excessive water intake. Any items obstructing the movement of this float should be carefully removed to ensure unimpeded functionality.
Moving on to the water inlet valve, a key player in the dishwasher’s water supply process, a series of checks are necessary. Begin by disconnecting the dishwasher from electrical power and shutting off the water supply valve. Subsequently, detach the water supply line from the water inlet valve.
Here, attention should be directed to the water inlet valve screen, where the accumulation of debris may result in clogs. If such clogs are identified, replacing the water valve is recommended to prevent potential flooding in the kitchen.
With the water supply line disconnected, briefly opening the water supply valve into a shallow pan allows for a visual check of water flow. If water fails to flow, consulting a plumber for repairs to the dishwasher’s water supply is advised.
Further examination involves checking the wiring connections on the water inlet valve. Reconnect any loose wires or replace the wire harness if damage is evident. If the wiring appears intact, the next steps involve potential replacement of either the water inlet valve or the electronic control board.
In summary, Maytag Dishwasher Error Code 6-1 or F6E1 necessitates a comprehensive troubleshooting approach, ranging from the overfill float to the water inlet valve and associated wiring. Seeking professional assistance may be warranted for a thorough assessment and resolution of the issue.
Maytag Dishwasher Error Code 5-2 or F5E2
Your Maytag dishwasher, equipped with advanced technology, communicates through error codes to alert you to potential issues. The 5-2 or F5E2 error code specifically signals that the control board detects a problem with the door not opening as expected between cycles. This is a crucial step in the dishwasher’s operational sequence, and failure to recognize the door opening can prevent the initiation of subsequent cycles.
Error Description:
The electronic control board anticipates the door to open between cycles. If it doesn’t register this action, the dishwasher assumes the door is still closed and won’t initiate the next cycle. This error is designed to ensure proper functioning and prevent potential safety hazards.
Troubleshooting Steps:
- Cancel the Cycle: If you didn’t manually open the door between cycles, start by canceling the current cycle. This action serves as a reset, allowing the dishwasher to reevaluate the door status.
- Open and Shut the Door: Following the cycle cancellation, manually open and securely close the dishwasher door. This ensures that the door switch registers the proper movement.
- Attempt a New Cycle: Initiate a new cycle to see if the dishwasher now recognizes the door’s status. If the cycle starts successfully, the issue may have been a momentary glitch.
- Door Switch Assessment: If the problem persists, the door switch may be defective. Unplug the dishwasher and then plug it back in to simulate the door opening. If the cycle starts after this simulation, it indicates a potential issue with the door switch.
- Replace Door Latch Assembly: In cases where the door switch isn’t detecting the door opening, consider replacing the door latch assembly. This component is integral to ensuring the proper functioning of the door switch.
Maytag Dishwasher Error Code 5-1 or F5E1
Encountering Error Code 5-1 or F5E1 on your Maytag dishwasher signals a door switch failure, a pivotal component for seamless operation. This code manifests when the dishwasher’s door isn’t closed within 4 seconds of pressing the Start/Resume button or when the door latch assembly is compromised.
When initiating a cycle, it’s crucial to ensure the door is securely closed within the specified timeframe. Failure to do so triggers this error. Additionally, a broken door latch assembly contributes to the issue.
Troubleshooting Steps:
-
Prompt Door Closure:
- Begin by closing the dishwasher door within 4 seconds after pressing Start/Resume. Ensure a swift and secure closure to reset the error.
-
Assessment of Door Switch Wire Harness:
- Unplug the dishwasher to disconnect electrical power, prioritizing safety.
- Disassemble the dishwasher door to access the door switch wire harness.
- Thoroughly inspect the wire harness for any loose connections or damage.
-
Wire Harness Maintenance:
- If loose wires are identified, carefully reconnect them to the door switch. Ensure a snug fit to guarantee a reliable connection.
- If the wire harness exhibits damage, replacement is recommended to restore optimal functionality.
-
Door Latch Assembly Inspection:
- Examine the door latch assembly for any signs of wear, breakage, or misalignment.
- If the latch assembly is faulty, consider replacing it to address the root cause of the door switch failure.
If troubleshooting steps do not resolve the issue, seeking the expertise of a certified technician is advised. Unplug the dishwasher and consult a professional to conduct a comprehensive assessment, ensuring that the door switch and latch assembly are in optimal working condition.
Don’t let Error Code 5-1 or F5E1 disrupt your dishwashing routine. Swift and meticulous attention to the door switch and latch assembly can restore your Maytag dishwasher to its efficient functionality.
Maytag Dishwasher Error Code 4-4 or F4E4
Encountering the Maytag Dishwasher Error Code 4-4 or F4E4 signals a breakdown in communication between the electronic control board and the circulation pump motor. This error disrupts the harmonious interaction crucial for the dishwasher’s optimal functioning.
Understanding the Issue:
The 4-4 or F4E4 error points to a disconnection or malfunction in the communication pathway linking the electronic control board and the circulation pump motor. This communication breakdown can stem from various factors, hindering the dishwasher’s ability to execute cycles effectively.
Troubleshooting Steps:
- Disconnect Power: Begin the troubleshooting process by unplugging the dishwasher from the electrical supply. This step ensures safety during inspection and potential repairs.
- Examine Pump Wire Harness: Investigate the circulation pump’s wire harness for any signs of damage or loose connections. A visual inspection might reveal disconnected or frayed wires.
- Reconnect or Replace Wires: If loose wires are identified, carefully reconnect them to their appropriate terminals. In the case of damaged wires, replacing the wire harness becomes essential to restore proper communication.
- Inspect Circulation Pump and Motor Assembly: Examine the circulation pump and motor assembly for any visible signs of malfunction or damage. Physical inspection may reveal issues such as impeller blockages or motor irregularities.
- Replace Circulation Pump and Motor: If issues persist after inspecting the wire harness and pump assembly, replacing the circulation pump and motor is recommended. This ensures a comprehensive solution to the communication error.
- Consider Electronic Control Board Replacement: If the problem persists even after circulation pump and motor replacement, the electronic control board may be at fault. Subsequently, replacing the electronic control board becomes a viable course of action to restore seamless communication.
While these troubleshooting steps offer a DIY approach, seeking professional assistance from technicians, like those at Appliance Repair Los Angeles, is advisable for a thorough diagnosis and precise resolution. Their expertise ensures the effective restoration of communication between the electronic control board and the circulation pump motor, bringing your Maytag dishwasher back to optimal functionality.