Maytag Dryer tripping breaker
The Circuit Breaker is Weak
Over time, circuit breakers can weaken. If the circuit breaker is weak, it may trip, even if the amperage draw from the dryer is below the breakers limit. If you have already checked all of the potentially defective dryer components, consider having an electrician replace the circuit breaker.
Maytag Dryer Heating Element
Sometimes, if the heating element fails, it shorts out against the heater housing, causing the dryer to trip the circuit breaker. To determine if the heating element is at fault, use a multimeter to test each terminal for continuity to the case. If the heating element has continuity to the case, it is shorted out. If the heating element is shorted out, replace it.
Maytag Dryer Heating Element Assembly
Sometimes, if the heating element fails, it shorts out against the heater housing, causing the dryer to trip the circuit breaker. To determine if the heating element assembly is shorted out, use a multimeter to test each terminal for continuity to the case. If the heating element assembly has continuity to the case, it is shorted out. If the heating element assembly is shorted out, replace it.
Maytag Dryer Power Cord
If the dryer’s power cord wire terminal connections are not secured properly to the terminal block, the terminal block can short out and cause a circuit breaker to trip or a fuse to blow. You should inspect both the terminal block and the power cord terminal connections for damage. If the power cord wire terminals are burnt or melted, you will need to replace the power cord.
Loose or Burnt Power Cord Connections
Loose or burnt power cord connections can cause restricted current flow, making the circuit breaker overheat and trip. Check the power cord connections at the dryer and receptacle for burnt prongs, wires, or terminals. If the power cord or terminal block is damaged it will need to be replaced.
Maytag Dryer Drive Motor
Sometimes, when the drive motor fails, it shorts out internally, causing the dryer to trip the circuit breaker. To determine if the drive motor is at fault, use a multimeter to test it for continuity. If the motor windings are shorted out, replace the drive motor.
Maytag Dryer Terminal Block
Electric dryer power cords attach to the dryer at a terminal block. If any of the wires on the terminal block are loose, they can arc and destroy part of the block. If this happens, one of the wires can short against the body of the dryer, causing the dryer to trip the breaker. This is not a common occurrence.