GE Oven Error Code: F7
If your GE oven is showing an F7 error code, it means that there is an issue with the key panel. Often the issue is that the oven is detecting that buttons are stuck or being pressed down at the same time. In most cases, the issue can be resolved by cleaning the ribbon cable, replacing the key panel, or replacing the control panel. An issue with the oven’s clock may also be responsible, which, on most models, will require that the control board be replaced.
For a temporary solution to the problem, the oven can be reset either by disconnecting the power to the oven for three minutes or by resetting the oven through the key panel (check the oven’s manual for reset instructions). The cause of the issue needs to be diagnosed and fixed to stop the error code from reappearing.
Check & Clean the Ribbon Cable
Occasionally, the F7 error code is caused by a loose or dirty ribbon cable. The ribbon cable connects the key panel with the control board. To access the ribbon cable, the panel covering the control board at the back of the oven needs to be removed. Once the panel is removed, the ribbon cable can be disconnected and cleaned with a pencil eraser or by purchasing an electrical cleaner.
The ribbon cable is usually disconnected from the control board and key panel by releasing tabs that hold the ribbon cable in place. When removing the ribbon cable, be careful not to damage the ribbon cable connectors. In some cases, simply removing and then reattaching the ribbon cable will solve the F7 issue.
To Check and Clean the Ribbon Cable:
- Disconnect the oven from the power source.
- Remove the screws to the oven’s back panel that covers the control panel. With the panel removed, you should see the control board and ribbon cable.
- Depress the tabs and gently pull the ribbon cable out from the control panel and key panel.
- Use a pencil eraser or apply an electrical cleaner to clean the ribbon. When using a pencil eraser, apply medium force to the copper connectors at the ends of the ribbon until the ribbon is cleaned. Remove signs of oxidation, like blackness, from the copper connectors.
- Reattach the ribbon cable to the control board and key panel. If using an electrical cleaner, make sure it has dried before reconnecting the ribbon cable.
- Reattach the control panel access panel and test the oven to see if the F7 issue has been resolved.
Control Board or Key Panel?
If cleaning and reconnecting the ribbon belt has not solved the F7 issue, you will likely need to replace either the key panel or control board. You may be able to diagnose the part responsible for the F7 error by visually inspecting the parts. If the control board has signs of burning or broken wires, it will most likely need to be replaced. If there are signs of moisture getting into the key panel, broken seals, or it is obvious that a key or two are stuck, the key panel will likely need to be replaced.
Depending on the model, if there are no visible signs of damage to either part, you may be able to determine which part is responsible by disconnecting the ribbon cable that connects the control board and key panel and leaving it detached for 24 hours. During this time, the oven should be observed to see if the F7 error code returns. If it returns, it indicates that the control board is responsible for the issue.
To check the control board and key panel:
- Disconnect the oven from the power source.
- Remove the screws securing the back panel that covers the control panel. With the panel removed, you should see the control board and ribbon cable.
- Detach the ribbon cable from the control board by depressing the tabs that hold it in place.
- For safety, put the back panel back on the oven by rethreading the screws.
- Restore power to the oven.
- Leave the oven for 24 hours, but watch to see if the F7 error code returns.
- If you see the F7 error code, it indicates that the control board will need to be replaced. If there is no F7 error code with the ribbon cable disconnected, it suggests that the key panel will need to be replaced.
Replacing the control board is typically a lot more expensive than replacing the key panel. Therefore, if you are unsure which part is responsible, seek professional advice before removing and replacing the part.
To remove and replace the key panel:
Note that access to the key panel may depend on the model of the GE oven that you have. Taking photos during the process, particularly of the wiring, may help to ensure the oven is reassembled correctly.
- Disconnect the oven from the power source.
- Remove the screws securing the back panel that covers the control panel.
- Remove the back panel from the oven so that you can access the control board.
- Depress the tabs that hold the ribbon cable in place, and detach the ribbon cable.
- Locate and remove two screws on each side of the oven that secure the heat deflector. Remove the heat deflector from the oven.
- Remove the screws securing the control board to the oven.
- Remove the screws that secure the spark module.
- Remove the screw holding the grounding wire to the oven to release the grounding wire.
- Remove the screws holding the console onto the oven frame.
- Remove the console and remove the screws securing the key panel to the console.
- Use a paint scraper and your fingers to peel off the key panel.
- Attach the new key panel to the key panel console.
- Reassemble the oven.
To remove and replace the control board:
- Disconnect the oven from the power source.
- Remove the screws securing the back panel that covers the control panel and lift the panel off.
- Depress the tabs that hold the ribbon cable in place, and detach the ribbon cable.
- Remove the screws securing the control board to the oven.
- Take a photo showing how the wires should be connected to the control board.
- Use needle-nose pliers to disconnect the wires from the control board.
- Install the new control board.
If you need to remove the original key panel from the old control board console, a heat gun can be used. The key panel should be carefully heated until it can be removed without causing damage. The key panel should then be refitted to the new control board console.
Schedule Appointment