Dacor Refrigerator Error Codes

Dacor Refrigerator Error Code F6

The Dacor refrigerator error code F6 indicates a communication error between the main board and display board. This can be caused by a loose or damaged connection, a faulty component, or a power surge.

Troubleshooting steps:

  1. Check the connections between the main board and display board. Make sure all connections are secure and free of corrosion. If you find any loose or damaged connections, repair or replace them as needed.
  2. Check the main board and display board for signs of damage. Look for cracks, burns, or other signs of physical damage. If you find any damage, replace the affected board.
  3. Test the power supply. Make sure the refrigerator is receiving the correct voltage and amperage. If the power supply is not working properly, replace it.

If you are comfortable working with electrical components, you can try to repair the communication error yourself

  1. Unplug the refrigerator from the power outlet.
  2. Remove the back panel of the refrigerator.
  3. Locate the main board and display board.
  4. Check the connections between the two boards.
  5. If you find any loose or damaged connections, repair or replace them as needed.
  6. Reinstall the back panel of the refrigerator.
  7. Plug the refrigerator back into the power outlet.

If the error code persists after you have completed these steps, you should contact a qualified technician for further diagnosis and repair.

Additional diagnostic tips:

  • If you have a multimeter, you can use it to test the voltage and amperage at the main board and display board.
  • You can also try resetting the refrigerator by unplugging it from the power outlet for 30 seconds and then plugging it back in.